No crank
The battery, the starter or a panel inhibit on the diesel set.
Open 24/7 · We arrive within 1 hour across Gauteng · Established 2000
Kohler diesel
We repair and service Kohler diesel standby generators across Gauteng. Kohler also builds gas and dual-fuel sets, so check the fuel on your data plate: for a diesel Kohler you are in the right place, and for a gas Kohler we have a dedicated gas service.
Independent service and repair: Kohler is a trademark of its owner, and ProService Generator Repairs is not a Kohler dealer or agent.
Callout fee waived when you accept our written quote. 1-year workmanship guarantee. See prices

Our Kohler diesel work covers standby sets that start, transfer and carry a building on diesel. We diagnose the start circuit, fuel system, cooling, controller and output in turn.
If your Kohler runs on natural gas, LPG or a gas-and-petrol arrangement, book Kohler gas generator repairs. The fuel on the plate decides which service fits.
We service Kohler diesel standby sets to the engine schedule on the plate, and we test the battery charger, because Kohler standby units often fail to crank after long idle spells.
Where an ATS is fitted, we test the transfer. A short unloaded exercise run checks that the set starts; a full service checks that it will carry your load.
We work on Kohler diesel standby sets where the installation allows. The Kohler plate gives us the kVA and the controller type, so a photo of it helps us plan.
When a Kohler diesel will not crank, we check the standby battery, the starter and any Kohler panel inhibit before ordering a fuel part.
When it cranks without firing, the usual causes are a blocked fuel filter, air in the line or a solenoid that does not open.
We diagnose the fuel path on the diesel engine fitted, confirming the filter type and lift pump from the engine hardware.
We trace rough running under load through fuel delivery before quoting injectors. Diesel that has stood for months in a standby tank is a common Kohler finding.
Kohler diesel sets use Kohler controllers or third-party panels, depending on the installation. We read the alarm from the panel on your set and trace it for that controller.
When a Kohler diesel runs but the building stays on mains, we test the ATS and the panel’s start output.
For overheating on enclosed sets, we check coolant, the radiator and airflow through the enclosure, and confirm a temperature trip on a long run before listing cooling parts.
We measure voltage at the breaker once engine speed is stable, then test the AVR and alternator.
On a Kohler diesel set, we check the engine, panel and output against your symptom.
Book a repair when your Kohler diesel fails to start, trips on load, shows a panel shutdown or loses output during an outage.
Book a service when fluids and filters are due and the set still runs on its exercise schedule.
A Kohler diesel can idle evenly and struggle when the building load comes on. We compare fuel delivery and alternator capacity to find which one runs out first.
A fuel or battery repair on a moderate-hour Kohler diesel is usually worthwhile. Major engine work on a high-hour installation needs a careful look at the alternatives.
When the engine, alternator and panel all need major work, we compare replacement with repair using the condition we measured.
Your cost depends on where the fault is and the parts for your engine and panel. Battery replacement, a common standby repair, typically costs R900 to R2,800.
The Kohler diesel faults we find most often, and our first checks.
The battery, the starter or a panel inhibit on the diesel set.
The fuel filter, air in the line or the solenoid.
A charger that is not keeping the standby battery topped up.
The ATS or the panel’s start output.
The AVR or alternator, once engine speed is stable.
We service Kohler diesel and Kohler gas sets, each with the right diagnostic approach.
We plan the visit from the fuel printed on your data plate.
We test the charger and battery, the most common cause of a Kohler no-start.
ProService Generator Repairs services and repairs Kohler generators, with the fault diagnosed and a written quote given before any work.
Yes. ProService services and repairs Kohler generators. We repair Kohler diesel standby sets on site, and we book gas Kohler sets as gas generator repairs.
Yes. We service and repair Kohler generators across Gauteng and give you a written quote before any work.
Yes. Gas and dual-fuel Kohler sets have their own service, Kohler gas generator repairs.
Usually the battery, a panel inhibit or fuel delivery. The cranking sound tells us where to start.
Yes. We change oil, filters and coolant, test the battery charger and read the controller alarms.
Yes. When the diesel runs but the building does not transfer, we trace the panel output and the ATS.
Check the fuel listed on the data plate, or send us a photo and we will tell you.
SDMO and Kohler-SDMO standby systems: controllers, ATS and fuel.
FG Wilson and Wilson standby sets: engine, controller, battery and ATS.
Generac diesel standby and commercial canopy sets.
Standby and commercial Cummins diesel sets: no-starts, fuel delivery, cooling and output faults.
We repair Kohler diesel standby sets at homes and businesses across Gauteng. We are open 24/7, and for a Kohler breakdown we arrive within 1 hour.
Send a photo of the Kohler data plate so we can confirm it is diesel, then call or WhatsApp 082 057 4605.